1992 No. 83 CUSTOMS (PROHIBITED EXPORTS) REGULATIONS (AMENDMENT) - REG 2
2. Schedule 9 (Goods the exportation of which is prohibited unless the approval of the Minister or an authorised person referred to in regulation 11 is produced to the Collector)
2.1 Item 25:
Omit the item, substitute:
"25
(1) Plants for the production of heavy water, deuterium or compounds
containing deuterium
(2) Equipment and materials suitable for plants in subitem (1), including:
(a) exchange towers that are:
(i) designed or prepared for production of heavy water by the water
- hydrogen sulphide exchange process; and
(ii) fabricated from fine carbon steel with a corrosion allowance of
at least 6 millimetres; and
(iii) between 6 and 9 metres (inclusive) in diameter; and
(iv) capable of operating at a pressure of at least 2 megapascals;
and
(b) single stage, low head (0.2 megapascals) centrifugal blowers or
compressors that:
(i) are designed or prepared for production of heavy water by the
water - hydrogen sulphide exchange process; and
(ii) have a throughput capacity of at least 56 cubic metres per
second at a pressure of at least 1.8 megapascals suction; and
(iii) have seals designed for wet hydrogen sulphide service; and
(c) ammonia - hydrogen exchange towers that are:
(i) designed or prepared for production of heavy water by the
ammonia - hydrogen exchange process:
(ii) at least 35 metres in height; and
(iii) between 1.5 metres and 2.5 metres (inclusive) in diameter; and
(iv) capable of operating at a pressure greater than 15 megapascals;
and
(v) made with at least one flanged axial opening, of the same
diameter as the cylindrical part of the tower, for use in
inserting and withdrawing tower internals; and
(d) tower internals and stage pumps designed or prepared for production of
heavy water by the ammonia - hydrogen exchange process, including:
(i) stage contactors for use within an ammonia - hydrogen exchange
tower to promote contact between liquid and gas; and
(ii) stage pumps for circulation of liquid ammonia; and
(e) ammonia crackers that:
(i) are designed or prepared for production of heavy water by the
ammonia - hydrogen exchange process; and
(ii) have an operating pressure of at least 3 megapascals; and
(f) catalytic burners designed or prepared for production of heavy water
by the ammonia - hydrogen exchange process by conversion of enriched
deuterium gas to heavy water; and
(g) infrared absorption analysers capable of on-line analysis of the ratio
of hydrogen to deuterium in a fluid with a deuterium concentration of
at least 90%".