BUILDING REGULATION 2006 - REG 24
What is a stage of assessable building work
24 What is a stage of assessable building work
(1) This section provides for what are the stages of assessable building work.
(2) Generally, the stages are all stages at which the building development
approval states the work must be inspected.
(3) If the work is the
construction of a single detached class 1a building, the stages also
include— (a) after excavation of foundation material and before the footings
for the building are laid; and
(b) if the building is to have a slab—after
the placement of formwork and steel for the slab but before the concrete for
the slab is poured; and
(c) to the extent the bracing for the frame of the
building consists of cladding or lining—after the cladding or lining has
been fixed to the frame; and
(d) to the extent the bracing for the frame of
the building does not consist of cladding or lining—before the cladding or
lining is fixed to the frame; and
(e) if reinforced masonry construction is
used for the frame of the building—before the wall cavities are filled; and
(f) at the completion of all aspects of the work.
(4) If the work is an
alteration to a single detached class 1a building, the stages also include
each stage mentioned in subsection (3) that is relevant to the alteration.
(5) If the work is the construction of, or an alteration to, a class 10
building or structure, other than a swimming pool, the stages also include at
the completion of the building or structure or the alteration.
(6) If the
work is the construction of, or an alteration to, a swimming pool, the stages
also include— (a) if a temporary fence for the pool is constructed— (i)
after the temporary fence for the pool is constructed and before the pool is
filled with water to a depth of 300mm or more; and
(ii) if the building
certifier for the work extends the period that the temporary fence for the
pool can be in place—before the extension is given; and
(b) at the
completion of the pool and its fencing and, if no temporary fence for the pool
was constructed, before the pool is filled with water to a depth of 300mm or
more.