A person conducting a business or undertaking at a workplace where general diving work is carried out must keep a dive safety log that contains the following information about each dive carried out by a worker—
(a) the name of the worker who carries out the dive;
(b) the name of any other person with whom the dive is carried out;
(c) the name of the person appointed under section 177 to supervise the diving work;
(d) the date and location of the dive;
(e) the time each diver enters and leaves the water;
(f) the maximum depth of the dive;
(g) any incident, difficulty, discomfort or injury that occurs or is experienced during the dive;
(h) if the dive was carried out using a dive computer—the dive time;
(i) if the dive was carried out using dive tables—the repetitive dive group, if available, and either the bottom time or the dive time;
(j) if the repetitive group and surface interval result in a repetitive factor—the surface interval and the repetitive factor;
(k) if the dive is carried out using EANx—(i) the oxygen content of the EANx; and(ii) the maximum operating depth of the EANx;
(l) if the dive is carried out using mixed gas—(i) the oxygen content and the nitrogen content (if any) of the gas; and(ii) the maximum operating depth of the mixed gas; and(iii) the minimum operating depth of the bottom mix.
Penalty—Maximum penalty—(a) for an individual—12 1 / 2 penalty units; or(b) for a body corporate—60 penalty units.