Specific control—flammable gases and vapours
72 Specific control—flammable gases and vapours
(1) A person conducting a business or undertaking must ensure, so far as is
reasonably practicable, that while work is being carried out in a
confined space, the concentration of any flammable gas, vapour or mist in the
atmosphere of the space is less than 5% of its LEL. Penalty— Maximum
penalty—60 penalty units.
(2) If it is not reasonably practicable to
limit the atmospheric concentration of a flammable gas, vapour or mist in a
confined space to less than 5% of its LEL and the atmospheric concentration of
the flammable gas, vapour or mist in the space is— (a) equal to or greater
than 5% but less than 10% of its LEL—the person must ensure that any worker
is immediately removed from the space unless a suitably calibrated,
continuous-monitoring flammable gas detector is used in the space; or
(b)
equal to or greater than 10% of its LEL—the person must ensure that any
worker is immediately removed from the space.
Penalty— Maximum
penalty—60 penalty units.