South Australian Current Regulations

[Index] [Table] [Search] [Search this Regulation] [Notes] [Noteup] [Previous] [Next] [Download] [Help]

WORK HEALTH AND SAFETY REGULATIONS 2012 - SCHEDULE 11

Schedule 11—Placard and manifest quantities

Regulations 347350, 361, 390 and 391

1—Determination of classification of flammable liquids

For the purposes of this table, if a flammable liquid category 4 is used, handled or stored in the same spill compound as one or more flammable liquids of categories 1, 2 or 3, the total quantity of flammable liquids categories 1, 2 or 3 must be determined as if the flammable liquid category 4 had the same classification as the flammable liquid in the spill compound with the lowest flash point.


Table 11.1

Column 1

Column 2

Column 3

Column 4

Column 5

Item

Description of hazardous chemical

Placard quantity

Manifest quantity

1

Flammable gases

Category 1A, category 1B or any combination of categories 1A and 1B

200L

5 000L

2

Gases under pressure

With acute toxicity, categories 1, 2, 3 or 4

50L

500L

3


With skin corrosion categories 1A, 1B or 1C

50L

500L

4


Not specified elsewhere in this Table

1 000L

10 000L

5

Flammable liquids

Category 1

50L

500L

6


Category 2

250L

2 500L

7


Category 3

1 000L

10 000L

8


Any combination of chemicals from Items 5 to 7 where none of the items exceeds the quantities in columns 4 or 5 on their own

1 000L

10 000L

9


Category 4

10 000L

100 000L

10

Self-reactive substances

Type A

5kg or 5L

50kg or 50L

11


Type B

50kg or 50L

500kg or 500L

12


Type C to F

250kg or 250L

2 500kg or 2 500L

13

Flammable solids

Category 1

250kg

2 500kg

14


Category 2

1 000kg

10 000kg

15


Any combination of chemicals from Items 11 to 14 where none of the items exceeds the quantities in columns 4 or 5 on their own

1 000kg or 1 000L

10 000kg or 10 000L

16

Pyrophoric liquids and pyrophoric solids

Category 1

50kg or 50L

500kg or 500L

17

Self-heating substances and mixtures

Category 1

250kg or 250L

2 500kg or 2 500L

18


Category 2

1 000kg or 1 000L

10 000kg or 10 000L

19


Any combination of chemicals from Items 16 to 18 where none of the items exceeds the quantities in columns 4 or 5 on their own

1 000kg or 1 000L

10 000kg or 10 000L

20

Substances which in contact with water emit flammable gas

Category 1

50kg or 50L

500kg or 500L

21


Category 2

250kg or 250L

2 500kg or 2 500L

22


Category 3

1 000kg or 1 000L

10 000kg or 10 000L

23


Any combination of chemicals from Items 20 to 22 where none of the items exceeds the quantities in columns 4 or 5 on their own

1 000kg or 1 000L

10 000kg or 10 000L

24

Oxidising liquids and oxidising solids

Category 1

50kg or 50L

500kg or 500L

25


Category 2

250kg or 250L

2 500kg or 2 500L

26


Category 3

1 000kg or 1 000L

10 000kg or 10 000L

27


Any combination of chemicals from Items 24 to 26 where none of the items exceeds the quantities in columns 4 or 5 on their own

1 000kg or 1 000L

10 000kg or 10 000L

28

Organic peroxides

Type A

5kg or 5L

50kg or 50L

29


Type B

50kg or 50L

500kg or 500L

30


Type C to F

250kg or 250L

2 500kg or 2 500L

31


Any combination of chemicals from Items 29 and 30 where none of the items exceeds the quantities in columns 4 or 5 on their own

250kg or 250L

2 500kg or 2 500L

32

Acute toxicity

Category 1

50kg or 50L

500kg or 500L

33


Category 2

250kg or 250L

2 500kg or 2 500L

34


Category 3

1 000kg or 1 000L

10 000kg or 10 000L

35


Any combination of chemicals from Items 32 to 34 where none of the items exceeds the quantities in columns 4 or 5 on their own

1 000kg or 1 000L

10 000kg or 10 000L

36

Skin corrosion

Category 1A

50kg or 50L

500kg or 500L

37


Category 1B

250kg or 250L

2 500kg or 2 500L

38


Category 1C

1 000kg or 1 000L

10 000kg or 10 000L

39

Corrosive to metals

Category 1

1 000kg or 1 000L

10 000kg or 10 000L

40


Any combination of chemicals from Items 36 to 39 where none of the items exceeds the quantities in columns 4 or 5 on their own

1 000kg or 1 000L

10 000kg or 10 000L

41

Unstable explosives


5kg or 5L

50kg or 50L

42

Unstable chemicals

Any combination of chemicals from Items 10, 28 and 41 where none of the items exceeds the quantities in columns 4 or 5 on their own

5kg or 5L

50kg or 50L

43

Aerosols

Category 1, category 2, category 3 or any combination of categories 1, 2 and 3

5 000L

10 000L

Note—

1         In item 2, Gases under pressure with acute toxicity, category 4 only applies up to a LC50 of 5000 ppmV. This is equivalent to dangerous goods of Division 2.3.

2         Item 43 includes flammable aerosols.

Example—

For placarding and manifest purposes, a spill compound containing 1 000L of flammable liquid category 1 and 1 000L of flammable liquid category 4 is considered to contain 2 000L of flammable liquid category 1.



AustLII: Copyright Policy | Disclaimers | Privacy Policy | Feedback