Electrical Products (Part 2 Declarations) Variation
Proclamation 2009
under section 5 of the Electrical Products Act 2000
Part 1—Preliminary
This proclamation may be cited as the Electrical Products (Part 2
Declarations) Variation Proclamation 2009.
This proclamation will come into operation on 1 January 2010.
In this proclamation, a provision under a heading referring to the
variation of a specified proclamation varies the proclamation so
specified.
Part 2—Variation of Electrical Products (Part 2
Declarations) Proclamation 2004
4—Variation of clause
5—Energy performance registration
Clause 5—after subclause (2) insert:
(3) For the purposes of item 1 (Air conditioner packaged) and item 2 (Air
conditioner—refrigerative) of Schedule 2, AS/NZS 3823.2:2009 as in force
as at 1 January 2010 is to apply with the following
modifications:
(a) section 3.2—delete the 2 paragraphs (leaving Tables 3.1
and 3.2) and substitute:
Air conditioners manufactured in Australia or New Zealand or imported after
the dates specified, shall meet or exceed the requirements in
Table 3.1A, Table 3.1 or Table 3.2, as applicable.
The requirements in Table 3.1A apply as follows:
(a) from 1 January 2010 until 31 March 2010 (inclusive) the
minimum EER requirements apply;
(b) from 1 April 2010 until 31 March 2011 (inclusive) the
minimum EER and the minimum COP requirements apply;
(c) on and from 1 April 2011 the minimum EER, minimum AEER and minimum
ACOP requirements apply.
Note—
For requirements in the previous edition of this Standard, see Appendix
H.
Reverse cycle products must meet the requirements for both heating and
cooling. In the case of reverse cycle products, the MEPS levels for heating and
cooling are based on the rated total cooling capacity. For the purposes of
determining the relevant MEPS level in Table 3.1A, Table 3.1 or Table 3.2,
rated capacity shall be rounded to the
nearest 0.1 kW.
TABLE 3.1A—MEPS—MINIMUM REQUIREMENTS FOR AIR
TO AIR HEAT PUMPS AND AIR CONDITIONERS AT RATED CAPACITY SOLD IN SOUTH
AUSTRALIA
Product Description |
Minimum EER 1 January 2010 |
Minimum COP 1 April 2010 |
Minimum AEER and/or ACOP 1 April 2011 |
---|---|---|---|
Non ducted unitary – all types, <10kW, all phases |
2.9 |
2.84 |
2.84 |
Non ducted unitary – all types, 10kW to <19kW, all
phases |
2.9 |
2.75 |
2.75 |
Non ducted split systems – all types, <4kW, all phases |
3.4 |
3.33 |
3.33 |
Non ducted split systems – all types, 4kW to <10kW, all
phases |
3.0 |
2.93 |
2.93 |
Non ducted split systems – all types, 10kW to <19kW, all
phases |
3.0 |
2.75 |
2.75 |
Ducted systems – all types, <19kW, all phases |
2.9 |
2.75 |
2.75 |
All configurations – all types, 19kW to 39kW, all phases |
3.1 |
3.05 |
3.05 |
All configurations – all types, >39kW to 65kW, all phases
|
2.9 |
2.75 |
2.75 |
(b) section 3.2, heading to Table 3.1—after "RATED CAPACITY"
insert:
SOLD IN PLACES OUTSIDE SOUTH AUSTRALIA
(c) section 3.3—delete "EER (AEER in 2011) and/or COP
(ACOP in 2011)" last occurring and substitute:
EER, AEER, COP and/or ACOP
(d) section 3.3—delete "EER (AEER in 2011) and/or COP
(ACOP in 2011)" wherever else occurring and substitute in each
case:
EER, AEER, COP and/or ACOP (as applicable)
(e) section 3.5—delete "EER (AEER in 2011)" and
substitute:
EER and/or AEER (as applicable)
5—Variation of Schedule
2—Energy performance registration
(1) Schedule 2, item 1—delete "AS/NZS
3823.22" and substitute:
AS/NZS 3823.2:2009 as in force as at 1 January 2010 with the modifications
specified in clause 5(3)2
(2) Schedule 2, item 2—delete "AS/NZS
3823.21" and substitute:
AS/NZS 3823.2:2009 as in force as at 1 January 2010 with the modifications
specified in clause 5(3)1
Made by the Governor
with the advice and consent of the Executive Council
on 16 December
2009
DPC09/022CS