South Australian Proclamations and Notices |
[Index] [Search] [Download] [Help]
South Australia
Electrical Products (Part 2 Declarations) Variation Proclamation 2010
under section 5 of the Electrical Products Act 2000
Part 1—Preliminary
1—Short title
This proclamation may be cited as the Electrical Products (Part 2 Declarations) Variation Proclamation 2010.
2—Commencement
This proclamation comes into operation on the day on which it is made.
3—Variation provisions
In this proclamation, a provision under a heading referring to the variation of a specified proclamation varies the proclamation so specified.
Part 2—Variation of Electrical Products (Part 2 Declarations) Proclamation 2004
4—Variation of clause 3—Interpretation
Clause 3(1)—after "In this proclamation" insert:
, unless the contrary intention appears
5—Variation of clause 5—Energy performance registration
Clause 5(2)—delete "as in force from time to time"
6—Variation of Schedule 2—Energy performance registration
(1) Schedule 2, after item 3 insert:
3A |
ELC, or ELV lighting converter (also known as a magnetic isolating transformer or an electronic step-down converter) being an electrical device that— (a) has an input from mains supply (usually 115 V/60 Hz, 230 V/50 Hz, 240 V/50 Hz or a range including some or all of those input conditions); and (b) is intended for use with ELV (extra low voltage) lamps with a single voltage output (either ac or dc) not exceeding 50 V; and (c) has a power rating not exceeding 500 VA. |
AS/NZS 4879.22 |
(2) Schedule 2, item 6A—delete item 6A and substitute:
6A |
Incandescent lamp, being— (a) a GLS (general lighting service) incandescent lamp with a nominal voltage of 220 V or more, a nominal wattage of less than 150 W and with the attributes set out in clause 1.1.2 of the standard, but not including a primary coloured lamp; or (b) an ELV (extra low voltage) halogen non-reflector type lamp (a gas filled lamp containing halogens or halogen compounds) with a filament consisting of tungsten, a nominal voltage of between 5 and 14 V inclusive and with the attributes set out in clause 1.1.3 of the standard; or (c) a candle lamp with a nominal voltage exceeding 220 V, a nominal wattage greater than 40 W and with the attributes set out in clause 1.1.4 of the standard, but not including a primary coloured lamp; or (d) a fancy round lamp with a nominal voltage exceeding 220 V, a nominal wattage greater than 40 W and with the attributes set out in clause 1.1.5 of the standard, but not including a primary coloured lamp; or (e) a decorative lamp with a nominal voltage exceeding 220 V, a nominal wattage greater than 40 W and with the attributes set out in clause 1.1.6 of the standard, but not including a primary coloured lamp or a pilot lamp; or (f) a mains voltage halogen non-reflector type lamp with a filament consisting of tungsten, a nominal voltage exceeding 220 V, and with the attributes set out in clause 1.1.7 of the standard, but not including a primary coloured lamp; or (g) an ELV (extra low voltage) halogen reflector type lamp with a nominal voltage of between 5 and 24 V inclusive and with the attributes set out in clause 1.1.8 of the standard, but does not include a lamp of the type referred to in clause 1.2 of the standard. |
AS/NZS 4934.2(Int): 2008 as in force as at 6 April 20102 |
Made by the Governor
with the advice and consent of the Executive Council
on 18 November
2010
MEN/10/002
[Published in the Gazette on 18 November 2010 at page 5358]