Schedule 8—Essential safety measures
Part 1—Building fire integrity
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Building elements required to satisfy prescribed fire-resistance levels |
2 |
Materials and assemblies required to have fire hazard properties |
3 |
Elements required to be non-combustible, provide fire protection, compartmentation or separation |
4 |
Wall-wetting sprinklers (including doors and windows required in conjunction with wall-wetting sprinklers) |
5 |
Fire doors (including sliding fire doors and their associated warning systems) and associated self‑closing, automatic closing and latching mechanisms |
6 |
Fire windows (including windows that are automatic or permanently fixed in the closed position) |
7 |
Fire shutters |
8 |
Solid core doors and associated self-closing, automatic closing and latching mechanisms |
9 |
Fire-protection at service penetrations through elements required to be fire-resisting with respect to integrity or insulation, or to have a resistance to the incipient spread of fire |
10 |
Fire protection associated with construction joints, spaces and the like in and between building elements required to be fire-resisting with respect to integrity and insulation |
11 |
Smoke doors and associated self-closing, automatic closing and latching mechanisms |
12 |
Proscenium walls (including proscenium curtains) |
Part 2—Means of egress
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Paths of travel to exits |
2 |
Discharge from exits (including paths of travel from open spaces to the public roads to which they are connected) |
3 |
Exits (including fire-isolated stairways and ramps, non fire-isolated stairways and ramps, stair treads, balustrades and handrails associated with exits, and fire-isolated passageways) |
4 |
Smoke lobbies to fire-isolated exits |
5 |
Open access ramps or balconies for fire-isolated exits |
6 |
Doors (other than fire or smoke doors) in a required exit, forming part of a required exit or in a path of travel to a required exit, and associated self-closing, automatic closing and latching mechanisms |
Part 3—Signs
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Exit signs (including direction signs) |
2 |
Signs warning against the use of lifts in the event of fire |
3 |
Warning signs on sliding fire doors and doors to non-required stairways, ramps and escalators |
4 |
Signs, intercommunication systems, or alarm systems on doors of fire-isolated exits stating that re-entry to a storey is available |
5 |
Signs alerting persons that the operation of doors must not be impaired |
6 |
Signs required on doors, in alpine areas, alerting people that they open inwards |
7 |
Fire order notices required in alpine areas |
Part 4—Lighting
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Emergency Lighting |
Part 5—Fire fighting services and equipment
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Fire hydrant system (including on-site pump set and fire-service booster connection) |
2 |
Fire hose reel system |
3 |
Sprinkler system |
4 |
Portable fire extinguishers |
5 |
Fire control centres (or rooms) |
Part 6—Air-handling systems
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Smoke hazard management systems— (a) automatic air pressurisation systems for fire‑isolated exits; (b) zone smoke control system; (c) automatic smoke exhaust system; (d) automatic smoke-and-heat vents (including automatic vents for atriums); (e) air-handling systems that do not form part of a smoke hazard management system and which may unduly contribute to the spread of smoke; |
| |
| |
| |
| |
|
(f) miscellaneous air-handling systems serving more than one fire compartment to which Sections 5 and 6 of AS/NZS 1668.1 The use of ventilation and air conditioning in buildings—Part 1: Fire and smoke control in buildings, as in force or as re-issued or as published from time to time; (g) other air-handling systems. |
2 |
Car park mechanical ventilation system |
3 |
Atrium smoke control system (see item 1(d) for smoke and heat vents) |
Part 7—Automatic fire detection and alarm systems
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Smoke and heat alarm system |
2 |
Smoke and heat detection system |
3 |
Atrium fire detection and alarm system |
Part 8—Occupant warning systems
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Sound system and intercom system for emergency purposes |
2 |
Building occupant warning system |
Part 9—Lifts
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Stretcher facilities in lifts |
2 |
Emergency lifts |
3 |
Passenger lift fire service controls |
Part 10—Standby power supply system
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Standby power supply system |
Part 11—Building clearance and fire appliances
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Open space around large isolated buildings |
2 |
Vehicular access around large isolated buildings |
Part 12—Mechanical ventilation and hot, warm and cooling water systems
Column 1 Item |
Column 2 Safety measure |
---|---|
1 |
Mechanical ventilation systems incorporating cooling tower systems (other than a system serving only a single sole-occupancy unit in a Class 2 or 3 building or a Class 4 part of a building) |
2 |
Mechanical ventilation systems incorporating hot and warm water systems (other than a system serving only a single sole-occupancy unit in a Class 2 or 3 building or a Class 4 part of a building) |