    (1)     In Schedule 34 to the Principal Regulations, in Part A, for items 34A to 34D substitute

    "34A     A T5 adaptor that—

        (a)     has a lamp with a minimum wattage of 14 watts; and

        (b)     has a power factor of at least 0∙9; and

        (c)     has a ballast made from rigid non-metallic material; and

        (d)     meets standards determined by the ESC when tested by an approved laboratory in accordance with a laboratory test approved by the ESC; and

        (e)     is listed in the ESC register.

    34B     A lighting control device, other than a voltage reduction unit, that is certified by the manufacturer as appropriate for use with the type of lamps it will be required to control.

    34C     A voltage reduction unit that—

        (a)     has an output voltage ascertained by an approved laboratory in accordance with a laboratory test approved by the ESC; and

        (b)     is not installed in conjunction with electronic ballasts; and

        (c)     is listed in the ESC register.

    34D     Any other lighting equipment that—

        (a)     is listed in the ESC register; and

        (b)     when installed, meets the minimum power factor determined by the ESC and specified on the ESC's Internet site; and

        (c)     meets standards determined by the ESC when tested by an approved laboratory in accordance with a laboratory test approved by the ESC.".

    (2)     In Schedule 34 to the Principal Regulations, in Part B—

        (a)     for "0∙963" substitute "1∙095";

        (b)     in Equation 1 , in the definition of baseline energy consumption , for "Part J6 of the 2011 edition of the Building Code or the 2012 edition of the Building Code" substitute "Part J6 of the Building Code as amended from time to time".

    (3)     In Schedule 34 to the Principal Regulations, in Part B, in Equation 2 —    

        (a)     in the definition of Each Space , for "Part J6 of the 2011 edition of the Building Code" substitute "Part J6 of the Building Code as amended from time to time";

        (b)     in the definition of IPD , for "Table J6.2a of the 2011 edition of the Building Code" substitute "Table J6.2a of the Building Code as amended from time to time";

        (c)     in the definition of Asset Lifetime, after paragraph (a) insert

    "(ab)     if, as part of the lighting upgrade—

              (i)     a lighting control device is installed in the space; and

              (ii)     no lighting equipment of any other type is installed in the space—

5 years; or";

        (d)     in the definition of Asset Lifetime , in paragraphs (b) and (c), after "Annual Operating Hours" insert ", to a maximum of 10 years";

        (e)     for the definition of Annual Operating Hours substitute

" Annual Operating Hours is—

        (a)     if the lighting upgrade is undertaken on a road or in a public or outdoor space that is not a sports field, other than the replacement or installation of traffic signals, 4500 hours; or

        (b)     if traffic signals are replaced as part of the lighting upgrade, 2920 hours; or

        (c)     if the lighting upgrade is undertaken in a space specified in column 2 of Table 3, the number of hours specified in column 3 of that Table in respect of that space as specified in column 2 of that Table; or

        (d)     if the lighting upgrade is undertaken in a space that is not specified in column 2 of Table 3 but that is specified in column 2 of Table 4, the number of hours specified in column 3 of Table 4 in respect of that space as specified in column 2 of that Table; or

        (e)     in any other case, 1000 hours.".

    (4)     In Schedule 34 to the Principal Regulations, in Part B, in Equation 3

        (a)     in the definition of Asset Lifetime , in paragraphs (a), (d) and (e), after "Annual Operating Hours" insert ", to a maximum of 10 years";

        (b)     after paragraph (a) insert

    "(ab)     if, as part of the lighting upgrade—

              (i)     a lighting control device is installed in the space; and

              (ii)     no lighting equipment of any other type is installed in the space—

5 years; or";

        (c)     for the definition of Annual Operating Hours substitute

        " Annual Operating Hours is—

        (a)     if the lighting upgrade is undertaken on a road or in a public or outdoor space that is not a sports field, other than the replacement or installation of traffic signals, 4500 hours; or

        (b)     if traffic signals are replaced as part of the lighting upgrade, 2920 hours; or

        (c)     if the lighting upgrade is undertaken in a space specified in column 2 of Table 3, the number of hours specified in column 3 of that Table in respect of that space as specified in column 2 of that Table; or

        (d)     if the lighting upgrade is undertaken in a space that is not specified in column 2 of Table 3 but that is specified in column 2 of Table 4, the number of hours specified in column 3 of Table 4 in respect of that space as specified in column 2 of that Table; or

        (e)     in any other case, 1000 hours.".

    (5)     In Schedule 34 to the Principal Regulations, in Part B, in Equation 4

        (a)     in the definition of Asset Lifetime , after paragraph (a) insert

    "(ab)     if, as part of the lighting upgrade—

              (i)     a lighting control device is installed in the space; and

              (ii)     no lighting equipment of any other type is installed in the space—

5 years; or";

        (b)     in the definition of Asset Lifetime , in paragraph (c), after "Annual Operating Hours" insert ", to a maximum of 10 years";    

        (c)     for the definition of Annual Operating Hours substitute

        " Annual Operating Hours is—

        (a)     if the lighting upgrade is undertaken on a road or in a public or outdoor space that is not a sports field, other than the replacement or installation of traffic signals, 4500 hours; or

        (b)     if traffic signals are replaced as part of the lighting upgrade, 2920 hours; or

        (c)     if the lighting upgrade is undertaken in a space specified in column 2 of Table 3, the number of hours specified in column 3 of that Table in respect of that space as specified in column 2 of that Table; or

        (d)     if the lighting upgrade is undertaken in a space that is not specified in column 2 of Table 3 but that is specified in column 2 of Table 4, the number of hours specified in column 3 of Table 4 in respect of that space as specified in column 2 of that Table; or

        (e)     in any other case, 1000 hours.".

(6)         In Schedule 34 to the Principal Regulations, in Part B, in Table 2, after item 5 insert

"6

Multiple Control Systems—where all lamps in the lighting system are connected to a programmable dimmer and manual dimmer

0∙76

7

Multiple Control Systems—any other combination of 2 or more control systems above

0∙6".

    (7)     In Schedule 34 to the Principal Regulations, in Part B, after Table 2 insert

" Table 3—Operating hours for lighting upgrades undertaken in certain spaces

Column 1


Item

Column 2


Type of space

Column 3
Annual operating hours
(hours per year)

1    

Auditorium, church and public hall

2000

2    

Board room and conference room

3000

3    

Carpark—general (undercover) and carpark—entry zone
(first 20 m of travel)

7000

4    

Carpark—general
(open air)

4500

5    

Common rooms, spaces and corridors in a Class 2 building

7000

6    

Courtroom

2000

7    

Dormitory of a Class 3 building used for sleeping only or sleeping and study

3000

Column 1


Item

Column 2


Type of space

Column 3
Annual operating hours
(hours per year)

8    

Health-care—children's ward, examination room, patient ward, all patient care areas including corridors where cyanosis lamps are used

6000

9    

Laboratory—artificially lit to an ambient level of 400 lx or more

3000

10    

Library—stack and shelving area, reading room and general areas

3000

11    

Lounge area for communal use in a Class 3 building or Class 9c aged care building

7000

12    

Maintained emergency lighting

8500

13    

Museum and gallery—circulation, cleaning and service lighting

2000

14    

Office

3000

15    

Restaurant, café, bar, hotel lounge and a space for the serving and consumption of food or drinks

5000

16    

Retail space including a museum and gallery whose purpose is the sale of objects

5000

17    

School—general purpose learning areas and tutorial rooms

3000

18    

Sole-occupancy unit of a Class 3 building

3000

19    

Sole-occupancy unit of a Class 9c aged care building

6000

20    

Storage with shelving no higher than 75% of the height of the aisle lighting

5000

21    

Storage with shelving higher than 75% of the height of the aisle lighting

5000

22    

Wholesale storage and display area

5000

Table 4—Operating hours determined by reference to building classification under the Building Code

Column 1


Item

Column 2


Type of space

Column 3
Annual operating hours
(hours per year)

1    

A space in the common area of a building that is classified as Class 2 under Part 3A of the Building Code as amended from time to time

7000

2    

A space in the common area of a building that is classified as Class 3 under Part 3A of the Building Code as amended from time to time

7000

3    

A space in a building that is classified as Class 3 under Part 3A of the Building Code as amended from time to time (other than a space in the common area of the building)

3000

4    

A space in a building that is classified as Class 5 under Part 3A of the Building Code as amended from time to time

3000

5    

A space in a building that is classified as Class 6 under Part 3A of the Building Code as amended from time to time

5000

6    

A space in an open air car park that is classified as Class 7a under Part 3A of the Building Code as amended from time to time

4500

7    

A space in a car park (other than an open air car park) that is classified as Class 7a under Part 3A of the Building Code as amended from time to time

7000

8    

A space in a building that is classified as Class 7b under Part 3A of the Building Code as amended from time to time

5000

Column 1


Item

Column 2


Type of space

Column 3
Annual operating hours
(hours per year)

9    

A space in a laboratory or building that is classified as Class 8 under Part 3A of the Building Code as amended from time to time and that is also classified as Division C in the Australian and New Zealand Standard Industrial Classification issued on 26 June 2013

5000

10    

A space in a laboratory or building that is classified as Class 8 under Part 3A of the Building Code as amended from time to time and that is not classified as Division C in the Australian and New Zealand Standard Industrial Classification issued on 26 June 2013

3000

11    

A space in a building that is classified as Class 9a under Part 3A of the Building Code as amended from time to time

6000

12    

A space in a building that is classified as Class 9b under Part 3A of the Building Code as amended from time to time

2000

13    

A space in a building that is classified as Class 9c under Part 3A of the Building Code as amended from time to time

6000

14    

A space in a structure that is classified as Class 10b under Part 3A of the Building Code as amended from time to time

1000

".