VICTORIAN ENERGY EFFICIENCY TARGET REGULATIONS 2008 (SR NO 158 OF 2008) - SCHEDULE 10

SCHEDULE 10

Sch. 10

Regulation 6(j)

SPACE AIR TO AIR HEAT PUMP

Prescribed activity under regulation 6(j): If the residential premises are in a non-gas reticulated area, installing a space air to air heat pump that complies with the criteria specified in Part A of Schedule 10.

PART A—CRITERIA

Item

    10A     A product complying with the MEPS requirement set out in AS/NZS 3823.2: 2005, achieving a minimum coefficient of performance of 3·5 when tested in accordance with AS/NZS 3823.1.1:1998 and a minimum rated output heating capacity of 2 kW as determined in accordance with AS/NZS 3823.1.1:1998 at the H1 temperature condition and listed in the ESC register.

PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES

The method and variables to be used to calculate in tonnes the carbon dioxide equivalent of greenhouse gases to be reduced by the installation of a product referred to in an item in Part A is determined by multiplying the abatement factor for that item by the regional factor applying to the place where the product is installed.

The following are the abatement factors and regional factors for each item in Part A:

Item

    10A     Abatement factor:

        (a)     If the product provides a rated output heating capacity of not less than 2 and not more than
3 kW as determined in accordance with
AS/NZS 3823.1.1: 1998 at the H1 temperature condition and has a coefficient of performance of—

              (i)     not less than 3·5 and not more
than 3·99:     5·21;

              (ii)     not less than 4 and not more than 4·49:     6·13;
Sch. 10

              (iii)     not less than 4·5 and not more
than 4·99:     6·85;

              (iv)     5 or more:     7·42;

        (b)     If the product provides a rated output heating capacity of 3 or more and not more than 6 kW as determined in accordance with AS/NZS 3823.1.1:1998 at the H1 temperature condition and has a coefficient of performance of—

              (i)     not less than 3·5 and not more
than 3·99:     9·89;

              (ii)     not less than 4 and not more
than 4·49:     11·65;

              (iii)     not less than 4·5 and not more
than 4·99:     13·01;

              (iv)     5 or more:     14·09;

        (c)     If the product provides a rated output heating capacity of more than 6 kW as determined in accordance with AS/NZS 3823.1.1:1998 at the H1 temperature condition and has a coefficient of performance of—

              (i)     not less than 3·5 and not more
than 3·99:     12·55;

              (ii)     not less than 4 and not more
than 4·49:     14·68;

              (iii)     not less than 4·5 and not more
than 4·99:     16·33;

              (iv)     5 or more:     17·65.

    10A     Regional factor:    

        (a)     If the product has a coefficient of performance
of not less than 3·5 and is installed in
metropolitan Victoria:     1·00;

        (b)     If the product has a coefficient of performance of not less than 3·5 and not more than 3·99 and—

              (i)     is installed in regional Victoria—
climatic region Mild:     0·07;
Sch. 10

              (ii)     is installed in regional Victoria—
climatic region Cold:     0·18;

              (iii)     is installed in regional Victoria—
climatic region Hot:     0;

Note that a certificate cannot be created for a space air to air heat pump installed in regional Victoria—climatic region Hot.

        (c)     If the product has a coefficient of performance of not less than 4·0 and not more than 4·49 and—

              (i)     is installed in regional Victoria—
climatic region Mild:     0·22;

              (ii)     is installed in regional Victoria—
climatic region Cold:     0·39;

              (iii)     is installed in regional Victoria—
climatic region Hot:     0·09;

        (d)     If the product has a coefficient of performance of not less than 4·5 and not more than 4·99 and—

              (i)     is installed in regional Victoria—
climatic region Mild:     0·34;

              (ii)     is installed in regional Victoria—
climatic region Cold:     0·58;

              (iii)     is installed in regional
Victoria—climatic region Hot:     0·20;

        (e)     If the product has a coefficient of performance of 5 or more and—

              (i)     is installed in regional Victoria—
climatic region Mild:     0·44;

              (ii)     is installed in regional Victoria—
climatic region Cold:     0·72;

              (iii)     is installed in regional Victoria—
climatic region Hot:     0·29.

PART C—TIME AT WHICH ACTIVITY UNDERTAKEN

Item
Sch. 10

    10A     At the beginning of the day on which the installed product is first able to produce and deliver heating.