Sch. 14
INSTALLATION OF PRODUCT ON SINGLE GLAZED WINDOW RAISING THERMAL EFFICIENCY
Prescribed activity under regulation 6(n): Installing on one or more single glazed windows in an external wall for a minimum glazing area of 5m 2 , a product that complies with the criteria specified in Part A of Schedule 14.
Item
14A A product that, when installed on a single
glazed window, results in a still air gap being created between the single
glazed window and the product and raises the thermal efficiency performance of
the window.
PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES
The method and variables to be used to calculate in tonnes the carbon dioxide equivalent of greenhouse gases to be reduced by the installation of a product referred to in an item in Part A is determined by multiplying the area of glazing (m 2 ) installed by the abatement factor for that item and by the regional factor applying to the place where the product is installed.
The following are the abatement factors and regional factors for each item in Part A:
Item
14A Abatement factor:
(a) If the product is glass or acrylic: 0·213;
(b) If the product is window film: 0·071.
14A Regional factor:
(a) If the product is installed in
metropolitan Victoria: 1·03;
(b) If the product is installed in
regional
Victoria—climatic region Mild: 0·92;
(c) If the product is installed in
regional
Victoria—climatic region Cold: 1·41;
(d) If the product is installed in
regional
Victoria—climatic region Hot: 0·74.
PART C—TIME AT WHICH ACTIVITY UNDERTAKEN
Sch. 14
Item
14A At the beginning of the day on which the installation of the product is completed.
__________________