Victorian Numbered Regulations

[Index] [Table] [Search] [Search this Regulation] [Notes] [Noteup] [Previous] [Next] [Download] [Help]

VICTORIAN ENERGY EFFICIENCY TARGET REGULATIONS 2008 (SR NO 158 OF 2008) - SCHEDULE 18

SCHEDULE 18

Sch. 18

Regulation 6(r)

HIGH EFFICIENCY REFRIGERATORS AND FREEZERS

Prescribed activity under regulation 6(r): Installing (purchasing) a high efficiency refrigerator or high efficiency freezer that complies with an item in Part A of Schedule 18.

PART A—CRITERIA

Item

    18A     Single door refrigerator listed in the ESC register—

        (a)     being a Group 1 refrigerator as defined by AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007; and

        (b)     having a total volume as determined in accordance with AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007 of not less than 100 litres and not more than 500 litres; and

        (c)     having a minimum star rating of 6·0 as determined in accordance with AS/NZS 4474.2:2001.

    18B     Two door refrigerator listed in the ESC register—

        (a)     being a Group 4, 5B, 5S or 5T refrigerator as defined by AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007; and

        (b)     having a total volume as determined in accordance with AS/NZS 4474.1:1997 or AS/NZS 4474.1.2007 of not less than 100 litres and not more than 700 litres; and

        (c)     having a minimum star rating of 4·5 as determined in accordance with AS/NZS 4474.2:2001.

    18C     Chest freezer listed in the ESC register—

        (a)     being a Group 6C product as defined by AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007; and

        (b)     having a total volume as determined in accordance with AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007 of not less than 100 litres and not more than 700 litres; and

        (c)     having a minimum star rating of 3·5 as determined in accordance with AS/NZS 4474.2:2001.

    18D     Upright freezer listed in the ESC register—

        (a)     being a Group 6U or 7 product as defined by AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007; and

        (b)     having a total volume as determined in accordance with AS/NZS 4474.1:1997 or AS/NZS 4474.1:2007 of not less than 100 litres and not more than 400 litres; and

        (c)     having a minimum star rating of 4·5 as determined in accordance with AS/NZS 4474.2:2001.

PART B—CALCULATION OF CARBON DIOXIDE EQUIVALENTS OF GREENHOUSE GASES

Sch. 18

The method and variables to be used to calculate in tonnes the carbon dioxide equivalent of greenhouse gases to be reduced by the installation of a product referred to in an item in Part A is determined by multiplying the abatement factor for that item by the regional factor applying to the place where the product is installed.

The following are the abatement factors and regional factors for each item in Part A:

Item

    18A     Abatement factor:    

{[0·5228 × (368 + 0·892 × V ff )] – CEC} × 0·01392

where V ff is the volume in litres of the fresh food compartment of the product and CEC is the comparative energy consumption specified on the energy rating label as defined by AS/NZS 4474.2:2001.

    18B     Abatement factor:    

{[0·4333 × (465 + 1·378 × (V ff + 1·6 × V fr ))] – CEC} × 0·01392

where V ff is the volume in litres of the fresh food compartment of the product, V fr is the volume of the freezer compartment and CEC is the comparative energy consumption specified on the energy rating label as defined by AS/NZS 4474.2:2001     .
Sch. 18

    18C     Abatement factor:

{[0·6889 × (248 + 1·072 × V fr )] – CEC] × 0·01719

where V fr is the volume of the freezer compartment and CEC is the comparative energy consumption specified on the energy rating label as defined by AS/NZS 4474.2:2001.

    18D     Abatement factor:

{[0·5007 × (439 +1·632 × V fr )] – CEC} × 0·01719

where V fr is the volume of the freezer compartment and CEC is the comparative energy consumption specified on the energy rating label as defined by AS/NZS 4474.2:2001.

    18A–18D Regional factor:

        (a)     If the product is installed in metropolitan
Victoria:     0·98;

        (b)     If the product is installed in regional Victoria:     1·04.

PART C—TIME AT WHICH ACTIVITY UNDERTAKEN

Item
Sch. 18

    18A–18D     At the beginning of the day on which the installation of the product is         completed.

__________________