This legislation has been repealed.
clause 46
Test methods and monitoring methods | ||
Air impurity | Test method | Monitoring method |
Solid particles (Total) | TM-15 | Not applicable |
Smoke, if determining whether a specified standard of concentration of opacity has been exceeded | Not applicable | CEM-1 |
Smoke, if determining whether a specified Ringelmann standard has been exceeded | TM-16 | Not applicable |
Averaging periods | |
Air impurity | Averaging period |
Solid particles (Total) | 1 hour, or the minimum sampling period specified in the relevant test method referred to in Part 1, whichever is the greater |
Smoke, if determining whether a specified standard of concentration of opacity has been exceeded | 6 minutes rolling |
Reference conditions relating to Group A | ||
Air impurity | Activity or plant | Reference conditions |
Solid particles (Total) | Any activity or plant, except as listed below | Dry, 273 K, 101.3 kPa |
Boilers or incinerators | Dry, 273 K, 101.3 kPa, 12% CO 2 | |
Smoke, if determining whether a specified standard of concentration of opacity has been exceeded | Any activity or plant | Gas stream temperature above dew point. Path length corrected to stack exit diameter as per CEM-1. |
Reference conditions relating to Group B or C | ||
Air impurity | Activity or plant | Reference conditions |
Solid particles (Total) | Any activity or plant, except as listed below | Dry, 273 K, 101.3 kPa |
Fuel burning equipment using solid fuel | Dry, 273 K, 101.3 kPa, 7% O 2 | |
Fuel burning equipment using liquid or gaseous fuel | Dry, 273 K, 101.3 kPa, 3% O 2 | |
Smoke, if determining whether a specified standard of concentration of opacity has been exceeded | Any activity or plant | Gas stream temperature above dew point. Path length corrected to stack exit diameter as per CEM-1. |