COAL MINING SAFETY AND HEALTH REGULATION 2017 - REG 189
Repairing and testing reeling, trailing and feeder cables
189 Repairing and testing reeling, trailing and feeder cables
(1) An underground mine’s safety and health management system must provide
for repairing and testing reeling, trailing and feeder cables.
(2) A person
must not use a reeling, trailing or feeder cable at an underground mine if the
cable— (a) has been found to be defective; and
(b) has not been effectively
repaired and tested under the system.
(3) Subsection (2) does not apply if—
(a) only the outer sheath of the cable is damaged; and
(b) before the cable
is used, the sheath is repaired in a way that satisfies a competent person
that the cable can be used without creating an unacceptable level of risk.
(4) In this section—
"competent person" means a person who is competent in assessing the level of
risk from a damaged cable.