COAL MINING SAFETY AND HEALTH REGULATION 2017 - REG 239
Other explosion-protected electrical plant
239 Other explosion-protected electrical plant
(1) This section applies to explosion-protected electrical plant supplied with
electricity by a trailing cable, other than plant— (a) mentioned in
sections 233 to 238 ; or
(b) having explosion protection category Ex ia; or
(c) operated in a NERZ.
(2) The plant must be fitted with at least 1
automatic methane detector to detect the general body concentration of methane
around the plant.
(3) The detector must automatically trip the electricity
supply to the plant when the concentration exceeds 2%.
(4) This section does
not apply to plant that is being operated in a location inspected periodically
by a person using a portable methane detector.
(5) In this section—
"periodically" , for inspecting plant in a location in an ERZ1, means at least
twice during a shift at approximately evenly spaced intervals.