COAL MINING SAFETY AND HEALTH REGULATION 2017 - REG 289
NERZ
(1) An underground mine, or any part of an underground mine, where the general
body concentration of methane is known to be, or is identified by a risk
assessment as likely to be, less than 0.5% is a negligible explosion risk zone
(a
"NERZ" ).
(2) Without limiting subsection (1) , a part of the mine submerged
by water is a NERZ.
(3) A NERZ may be divided into sub-zones to enable
discrimination to be applied to tripping of the electricity supply to
electrical circuits caused when gas detectors detect a general body
concentration of methane of 0.5%.
(4) Each sub-zone mentioned in subsection
(3) is a NERZ.
(5) Nothing in this section prevents the underground mine
manager for an underground mine from classifying a NERZ at the mine as an ERZ0
or ERZ1.
(6) If an underground mine manager makes a classification under
subsection (5) , the NERZ is taken, while the classification is in force, to
be an ERZ of the type stated in the classification.